Anderic UC7067FCRX Thermostatic Ceiling Fan Receiver Installation Guide
Aydan
Last Update vor 3 Monaten

Compatibility
Compatible with LCD-Type Thermostatic Remotes:
- Hampton Bay / Harbor Breeze CHQ7096T (with Timer key) Thermostatic Remote Control
- Anderic RR7096T (with Timer key) Thermostatic Remote Control
- Hampton Bay / Harbor Breeze UC7087T (with Timer key) Thermostatic Remote Control
- Anderic RR7087T (with Fan Timer key) Thermostatic Remote Control
- Anderic RR7096TR (with Reverse Key) Thermostatic Remote Control (Please note that the REV button may require a Reverse Module, only for select fan models)
- Anderic RR7099T (non-thermostatic) LCD Remote Control
Installation
Receiver Installation instructions:
Remove the ceiling fan canopy from the mounting bracket.
Disconnect the existing wiring between the ceiling fan and supply at the electrical junction box. If you already have a receiver installation (and are replacing it), please disconnect all wires.
Lay the black antenna wire on top of the receiver and put the receiver in the mounting bracket (Fig. C).
Make the following connections using the wire nuts supplied (Fig. D).
- Reinstall the canopy housing to the ceiling covering all wires.
- Take note of the dip-switches pattern for pairing
with the remote.
Connect | To |
Green Fan wire | Bare supply wire |
Black receiver wire (AC IN L) | Black supply wire |
White receiver wire (AC IN N) | White supply wire |
White receiver wire (TO MOTOR N) | White fan wire |
Black receiver wire (TO MOTOR L) | Black fan wire |
Blue receiver wire (FOR LIGHT) | Blue lights wire |
Push all connected wires up into the junction box.
Reinstall the canopy on the mounting bracket.
Restore the electrical power.