[User Guide] Anderic FAN10R/FAN9T Installation, Pairing, And Operating Guide

Aydan

Last Update a month ago

Anderic FAN10R / FAN-10R Replacement Ceiling Fan Receiver for Hampton Bay

Anderic FAN9T/REV Thermostatic without Dimming for Hampton Bay Ceiling Fan Remote Control

Anderic FAN10R/FAN9T Replacement Ceiling Fan Kit for Hampton Bay Ceiling Fan Remote Control Kit

Receiver Installation Instructions 

  1. Turn the power off to the fan from the circuit breaker box. 
  2. Remove the screws from the receiver cover (located on top of the motor housing). 
  3. Remove any zip ties holding down the wires (if necessary). 
  4. Remove any screws holding down the receiver (if necessary). 
  5. Disconnect the 9-pin connector plug. 
  6. Install the new receiver using the steps
    above in reverse order. 
  7. Take note of the dip-switches pattern (FIG. 1) for pairing with the remote in the next step.

Pairing with remote

Note: This unit has a total of 16 different code
combinations using the four dip-switches located in the battery compartment of the remote and on the receiver. See FIG 1. 

  1. On the remote: Remove the battery cover and set the dip-switches to any pattern. 
  2. On the receiver: Set the dip-switches to the same pattern as the remote. See diagram FIG.1.


Please view the link below for our dip switch guide.

https://www.anderic.help/article/pairing-your-ceiling-fan-remote-with-dip-switches

FAN9T Operating Guide

[FANAUTO]: Switches fan between Manual/Auto

[FAN SWITCH]: Press once for low speed, twice for medium speed, three times for high speed, and four times to turn the fan off

[SET TIMER]: Sets timer for fan and light 

[LIGHT]: Press once to power on the lights. Press twice to power off the lights.

[TEMP/SETHOURUP]: Set temperature or timer up

[TEMP/SETDOWN]: Sets temperature or timer down

[LIGHTDELAY]: Turns light on for 3 minutes

[FOR/REV]: Change the directions of the fan blades